  Detector (2 box system) Detector 3 (3 box system)
Scanning Heights 12", 18", 24", 36", 48"
(30, 45, 61, 91, 121 cm)
12 models 6" to 72" in 6" incr.
(15 to 183 cm in 15.3 cm incr.)
Scanning Range
Standard: Up to 25 feet (7.6 m);
Extended: Up to 50 feet (15.3 m)
Interchangeability
Transmitter and receivers are not matched sets.
Beam Spacing 3/4" (1.9 cm)
Object Sensitivity 1-1/4" (3.2 cm)
Angle of Divergence/Acceptance less than ±5° less than ±3-1/2°
CE: less than ±2-1/2°
Blanking/Floating External Blanking Windows required External
Optional 1 beam floating
Blanking Windows required,
1 beam Floating capability
Response Time 30 mSec max - 12" to 24"
50 mSec max - 36" to 48"
25 mSec max - 6 to 48"
35 mSec max - 54" to 72"
75 mSec max - "W" series (weld applications)
Warranty
Two years
OUTPUTS
  2 "captive contact" stop relays 2 "captive contact" stop relays,
plus 1 auxiliary relay and 4 SS indicator outputs
Stop Circuit/Lockout 4A @ 115 VAC or DC resistive Std:
2 NO contacts; Opt: 1 NO and 1 NC
4A @ 115 VAC or DC resistive *
NO or NC contacts avail. with all 3 relays
Indicator outputs Not applicable 4 open collector NPN, opto-isolated
70V @ 2 mA max
INPUTS
Power 110-120 VAC 50-60 Hz; 7 watts transmitter
12 watts receiver; 220 VAC option available
115-230 VAC 50-60 Hz,
27 watts max. Optional: 24 Vdc option
Transmitter/Receiver Sets One set per system, with no wiring
between the transmitter and receiver
Two sets (any height) can be
connected to same control box
MPCE Monitor Input Not applicable Dry contacts rated 20 mA @ 20 Vdc
20 mSec response time max
Remote Interrupt Input Closure to ground. Max on voltage 2V @ 2 mA
Remote Lockout Input Not applicable Same as above
Remote Reset Input Not applicable Same as above
INDICATORS
  Transmitter: Amber (power)
Receiver: Green (clear), Red (obstruct),
and flashing Red (Floating ON)
Transmitter & Receiver same as 2-box;
Flashing amber (Floating ON);
Box: Green (clear), Red (stop signalled), Yellow (reset required)
CONSTRUCTION
Transmitter and Receiver 18 gauge welded steel Extruded aluminum
0.12" (3 mm) wall minimum
Control Box (dimensions) Not applicable Lockable, 14 gauge welded steel
with keylock incl.; Enclosure*
7" x 9" x 3.5" (17.8 x 22.9 x 8.9 cm).
Panel Mt. 4" x 10" x 8" (10 x 25 x 20 cm)
Cables (dimensions) Not applicable 5, 15, 25, 50 and 100'
(1.5, 4.5, 7.5, 15, 30 cm)*
ENVIRONMENTAL
Transmitter and Receiver NEMA 4 hosedown, IP65 NEMA 4/IP65; Optional
explosion- proof enclosures
Control Box Not applicable NEMA 2/IP52; Opt. NEMA 4/IP65;
Opt. explosion-proof enclosure
Cables Not applicable NEMA 4 connector; Oil-resistant
PVC cable std.; Opt. S00W-A cable*
Vibration 10g, 0.03" displacement; freq. ; 10-150 Hz sine, per UL491 (3 axes)
Shock testing 50g, 11 mS pulse per MIL-STD-810C,; Method 516, Procedure I (3 axes)
WEIGHT
Transmitter or Receiver 8, 11, 13, 19, 23 lb
(3.6, 5, 5.9, 8.6, 10.4 kg)
Heads: 6" = 1.4 lb (.64 kg); Add
0.9 lbs (4 kg) for every additional
6" in height; Box - 9 lb (4 kg)*
Operating Temperature -4° to 122° F (-20° to 50° C)
Agency Approvals UL 491, CSA, BS 6491 (AMTRI) CSA (NRTL/C)
CE Compliance Not available Available (CE by TUV)
*Detector 3X Series Control available with the following differences: Dimensions: 9" x 13" x 4.2" (23 x 33 x 11 cm); Weight: 11 lb (5 kg); 2 stop outputs with 3 sets of NO contacts each; quick-disconnect for 2 sets of optic heads; Harting 24E or Sine V431 connector for power and I/O, SOOW-A cables with quick-disconnects at both ends.

Download TUV Certification PDF