Honeywell Sensing and Control is one of the world's largest single source suppliers
of sensors and switches.
Advantage
Page for:
- Product Manuals
- Product Drawings
- Configurators
- Software
- Latest Catalog
- And More
|
|
FP2000 PRESSURE TRANSDUCERS
| Gauge |
- Absoluete
|
- Differential
|
- Barometric
|
- Vacuumm
|
Honeywell's FP2000 pressure transducers are designed specifically for
flexible configurations and fast delivery. Small size and rugged
construction make all models of the FP2000 Series ideal
for applications in industrial, chemical, aerospace, semiconductor
and other areas where delivery and performance are critical.
Two Accuracy Levels: 0.1% and 0.25%
Four Different Outputs: mV/V, 4-20 mA (2 wire), 10 VDC (3 wire)
and 0-5 VDC (3 wire)
|
Gauge Models |
Absolute Models |
Differential
Wet/Wet Models |
Differential
Wet/Dry Models |
Barometric |
Vacuum |
| FPG1 |
0.1% |
FPA1 |
0.1% |
FDW1 |
0.1% |
FDD1 |
0.1% |
FPB1 |
0.1% |
FPV1 |
0.1% |
| FPG2 |
0.25% |
FPA2 |
0.25% |
FDW2 |
0.25% |
FDD2 |
0.25% |
FPB2 |
0.25% |
FPV2 |
0.25% |
|
gauge |
Differential*
|
Absolute
|
Barometric
|
Vacuum |
Available
Ranges:
for
international
calibrations &
additional
ranges, consult
Honeywell Sensotec |
10" H20,
0-1, 5, 15, 30, 50, 100, 150, 250, 500, 750, 1000, 1500,
2500, 5000, 7500, 10000 psig |
10" H20,
0-1, 5, 15, 30, 50, 100, 150, 250, 500, 750, 1000 psid |
0-5, 15,
30, 50, 100, 150, 500, 750, 1000, 1500, 2500, 5000, 7500,
10000 psia |
16-32" Hga,
26-32" Hga, 0-30" Hga |
10" H20,
0-1, 5, 10, 15 psiv |
Accuracy
(BFSL): |
±0.1%
or ±0.25% FS are available in all ranges |
±0.1%
or ±0.25% FS are available in all ranges
(for positive differential
pressure) |
±0.1%
or ±0.25% FS are available in all ranges |
±0.1%
or ±0.25% FS are available in all ranges |
±0.1%
or ±0.25% FS are available in all ranges |
Outputs
and
Excitation:**
intrinsically
safe available
for 4-20 mA
only up to
5000 psi |
For Specified Ranges With 0.1% Accuracy
Outputs-Millivolts for FPG1, FPA1, FDW1 and FDD1 are:
50 mV for ranges 5 psi and above; 25 mV to 50 mV for ranges
below 5 psi
Excitation-10 VDC |
For Specified Ranges With 0.25%
Accuracy
Outputs-Millivolts for FPG2, FPA2, FDW2 and FDD2 are:
100 mV for ranges 5 psi and above; 25 mV to 50 mV for
ranges below 5 psi
Excitation-10 VDC |
|
All models with 4-20 mA Outputs have
a Power Requirement of 9-28 VDC unregulated |
|
All models with 0-5 VDC Outputs have
a Power Requirement of 9-28 VDC unregulated |
Over
Pressure: |
All operating ranges can be exceeded
by 4x FS
or 2000 psi, whichever is less |
Positive Side: 4x full differential pressure
or 2000 psi, whichever is less
Negative Side: 4x full differential pressure
or 200 psi, whichever is less |
All operating ranges can be exceeded
by 4x FS
or 2000 psi, whichever is less |
Line
Pressure: |
N/A |
500 psi |
N/A |
Media
Compatibility: |
Wetted materials Ha C276 & 316L stainless
steel |
Wet Ports: Wetted materials Ha C276 &
316L stainless steel
Dry Ports: Wetted materials aluminum, silicone, silicon,
structural adhesive, quartz, steel |
Wetted materials Ha C276 & 316L stainless
steel |
Operating
Temperature: |
-10ºF to 200ºF |
Compensated
Temperature: |
40ºF to 140ºF
40ºF to 110ºF (for 10" H20 and 1 psi) |
Temperatue
Error Band: |
All models with 0.1% FS accuracy have
Temperature Error Bands of ±0.5% FS
(with the exception of 10" H20 which is ± 1% FS and 1
psi which is ± .75% FS)
All models with 0.25% FS accuracy have Temperature Error
Bands of ±1.0% FS.
(with the exception of 10" H20 which is ± 1.5% FS)
|
* The Wet/Wet Differential Pressure
Transducer has two separate, welded hastelloy diaphragms. In
the Wet/Dry Differential Pressure Transducer, the wet (Hi port)
has all-welded stainless and Hastelloy construction. The dry
port (Lo port)does not have an interface diaphragm.
** For other ranges and outputs, please
consult factory.
Flexibility is the Key
The FP2000 Series are configurable pressure transducers
designed to meet customer-specific applications and yet be delivered
quickly. By using a wide set of common, pre-tested interchangeable
parts, subassemblies and accessories, we can offer over 4000
transducer variations in the FP2000 Series.
|
|
|
|
15 PSI & ABOVE
gauge OR ABSOLUTE |
5 PSI
gauge OR ABSOLUTE |
DIFFERENTIAL-WET/WET
IN-LINE |
DIFFERENTIAL-WET/DRY
ANGLED |
BACK END OPTIONS
(see table below) |
BACK END OPTIONS
(see table below) |
|
|
PRESSURE ADAPTER OPTIONS
(see table below) |
PRESSURE ADAPTER OPTIONS
(see table below) |
| PRESSURE ADAPTER
OPTIONS |
|
|
Wiring Codes
|
OPTIONAL TRANSDUCER OUTPUTS |
|
|
2u(mV) |
Plug
Pins |
Designation |
Wire
End |
|
|
2n, 2p & 2y(4-20 mA) |
Plug
Pins |
Designation |
Wire
End |
|
|
2d & 2e(0-5 VDC) |
Plug
Pins |
Designation |
Wire
End |
|
|
2g & 2f (0-10 VDC) |
Plug
Pins |
Designation |
Wire
End |
|
Mini DIN Electrical
Connector (only)
Order Code AA161 |
| 1 |
(+) Excitation |
|
| 2 |
(+) Output |
|
| 3 |
(-) Output |
|
| GND |
(-) Excitation |
|
|
| 1 |
(+) Supply 9-28 VDC |
|
| 2 |
(+) Output 4-20 mA |
|
| 3 |
N/C |
|
| GND |
N/C |
|
|
| 1 |
(+) Supply 9-28 VDC |
|
| 2 |
(+) Output 0-5 VDC |
|
| 3 |
(-) Output/Supply
Return |
|
| GND |
N/C |
|
|
| 1 |
(+) Supply 12-28 VDC |
|
| 2 |
(+) Output 0-10 VDC |
|
| 3 |
(-) Output/Supply
Return |
|
| GND |
N/C |
|
|
Bendix Electrical
Connector (only)
Order Code AA111 |
| A |
(+) Excitation |
(Red) |
| B |
(+) Excitation |
|
| C |
(-) Excitation |
(Black) |
| D |
(-) Excitation |
|
| E |
(-) Output |
(Green) |
| F |
(+) Output |
(White) |
Bendix Connector & 15 Ft.
Cable Assembly Order Code AA113 |
|
| A |
(+) Supply 9-28 VDC |
(Red) |
| B |
N/C |
|
| C |
N/C |
|
| D |
(+) Output 4-20 mA |
(Black) |
| E |
N/C |
|
| F |
N/C |
|
Bendix Connector & 15
Ft.
Cable Assembly Order Code AA116 |
|
| A |
(+) Supply 9-28 VDC |
(Red) |
| B* |
(-) Supply Return |
(Black) |
| C* |
(-) Output Common |
(Green) |
| D |
(+) Output 0-5 VDC |
(White) |
| E |
N/C |
|
| F |
N/C |
|
Bendix Connector & 15
Ft.
Cable Assembly Order Code AA117 |
|
| A |
(+) Supply 12-28 VDC |
(Red) |
| B* |
(-) Supply Return |
(Black) |
| C* |
(-) Output Common |
(Green) |
| D |
(+) Output 0-10 VDC |
(White) |
| E |
N/C |
|
| F |
N/C |
|
Bendix Connector & 15
Ft.
Cable Assembly Order Code AA117 |
|
5 Ft. Integral
Transducer Cable
Option Code 6Q |
|
(+) Excitation |
(Red) |
|
(-) Excitation |
(Black) |
|
(-) Output |
(Green) |
|
(+) Output |
(White) |
|
|
(+) Supply 9-28 VDC |
(Red) |
|
(+) Output |
(Black) |
|
|
|
|
|
|
|
|
(+) Supply 9-28 VDC |
(Red) |
|
(-)* Supply
Return |
(Black) |
|
(-)* Output Common |
(Green) |
|
(+) Output 0-5 VDC |
(White) |
|
|
(+) Supply 12-28 VDC |
(Red) |
|
(-)* Supply
Return |
(Black) |
|
(-)* Output Common |
(Green) |
|
(+) Output 0-10 VDC |
(White) |
|
* = Connect together internally
Mating Connectors
|
Accessory
Code |
| Mini DIN only |
AA161 |
| Bendix connector
only |
AA111 |
| Bendix with 15' cable
(mV/V) |
AA113 |
| Bendix with 15' cable
(4-20 mA) |
AA116 |
| Bendix with 15' cable (0-5 VDC) |
AA117 |
|