| We offer a wide range
of water products, which are detailed below, please feel free
to download the Installation Manuals and Data Sheets all of
which will require the free Adobe Acrobat Reader to view.
If you cannot find what you
are looking for, please email us at:
water.control@honeywell.com
BACKFLOW
PREVENTERS
Backflow Preventers protect
the water supply from pollution and contamination.
Honeywell manufactures and supplies a range of devices from
simple check valves to the more complex Reduced Pressure Zone BA Device.
RV281
½"-2" BSP Female connection. For use with water
, compressed air and light fuel oils. Brass body with NBR lip seal and stainless steel
spring.
RV283P
Flanged connections PN16 sizes DN40-DN300. Versions with
NBR or EPDM lip seal ring. Powder coated cast iron housing.
BA295
½"-2" BSP Male connection tails.
Dezincification
resistant brass housing. Offers optimum protection to Drinking water supplies where a
Category 4 risk exists as defined by the Water Supply (Water Fittings) Regulations 1999.
Maximum inlet pressure 10 bar, Minimum inlet pressure 1.5 bar.
Please note that this device is KIWA approved.
BA298F
Flanged connections DN65-DN150 to PN10. Stainless Steel
body, lightweight to aid installation. Offers optimum protection to Drinking water
supplies where a Category 4 risk exists as defined by the Water Supply (Water Fittings)
Regulations 1999. Maximum inlet pressure 10 bar, Minimum inlet pressure 1.5 bar. BA298I also available as above with full stainless steel components for
use in food process and other applications where non ferrous metals are not permitted or
there exists a high risk of corrosion.
WATER
FILTERS
Honeywell manufactures and supplies a range of filtration
product from simple Y strainers to fully automated reverse rinse filters. A range of
filtration products are also available for retrofit installation to Pressure
Reducing Valves.
FY30
Brass Y strainer with threaded connections
3/8"-2" Mesh sizes 0.35mm and 0.18mm available as standard.
FY32
Red Bronze Y Strainer with threaded connections
¼"-2". Mesh size 0.25mm available as standard.
FY69P
Powder coated cast iron Y Strainer with flange connections
DN15-DN200. Mesh size 0.5mm available as standard.
F76S
Reverse rinsing fine filter with threaded connections
½"-2". The fine filter prevents the ingress of foreign bodies, for example rust
particles and grains of sand. Minimum pressure of 1.5 bar required for rinsing operation.
Mesh sizes 20, 50, 100 and 200 micron available as standard. The addition of the Z11 Actuator enables automated rinse
operation at intervals adjustable between four minutes and three months. For fully
automated optimum protection the addition of the DDS76 Differential
Pressure Switch ensures that should the mesh become blocked during operation
the filter will automatically enter reverse rinse mode. Setting range of 0.1 to 1.6 bar.
WRAS Approved.
F76S-F
Reverse rinsing fine filter with flanged connections to
PN16, sizes DN65 to DN100. The fine filter prevents the ingress of foreign bodies, for
example rust particles and grains of sand. Minimum pressure of 1.5 bar required for
rinsing operation. Mesh sizes 105/135 and 200 micron available as standard.
DDS76
For fully automated optimum protection the addition of the DDS76 Differential
Pressure Switch ensures that should the mesh become blocked during operation the
filter will automatically enter reverse rinse mode. Setting range of 0.1 to 1.6 bar. WRAS
Approved.
Z11
The addition of the Z11 Actuator
enables automated rinse operation at intervals adjustable between four minutes and three
months.
PRESSURE CONTROL VALVES
Honeywell manufactures and supplies a range of pressure
control valves for all applications. Pressure reduction and pressure regulation are
catered for as well as more sophisticated applications such as Differential Pressure
control.
D04
Pressure reducing valve with balanced seat. Protects water
installations against excessive pressure. The outlet pressure is set by turning an adjustment
knob, there is a connection provided for the optional pressure
gauge. Maximum inlet pressure 10 bar, outlet pressure 1.5 to 6 bar.
Connection by internal thread, 1/2" and 3/4"
connections.
D05F
Pressure reducing valve with balanced seat. Protects water
installations against excessive pressure. Features an integral fine filter to protect the
fully serviceable valve insert. The outlet pressure is set by turning an adjustment knob,
negating the need of a gauge. Maximum inlet pressure 25 bar, outlet pressure 1.5 to 6 bar.
Both internal and external connections is sizes 1/2",
3/4" and 1".
D06F
Pressure reducing valve with balanced seat. Protects water
installations against excessive pressure. Features an integral fine filter to protect the
fully serviceable valve insert. The outlet pressure is set by turning an adjustment knob,
negating the need of a gauge. Maximum inlet pressure 25 bar, outlet pressure 1.5 to 6 bar.
Tail piece connections enable easy in situ installation. ½" to 2" BSP
connections.
D06FN
Pressure reducing valve with balanced seat. Protects water
installations against excessive pressure. Features an integral fine filter to protect the
fully serviceable valve insert. The outlet pressure is set by turning an adjustment knob,
negating the need of a gauge. Maximum inlet pressure25 bar, outlet pressure 0.5 to 2 bar.
Tail piece connections enable easy in situ installation. ½" to 2" BSP
connections.
D06FH
Pressure reducing valve with balanced seat. Protects water
installations against excessive pressure. Features an integral fine filter to protect the
fully serviceable valve insert. The outlet pressure is set by turning an adjustment knob,
negating the need of a gauge. Maximum inlet pressure25 bar, outlet pressure 1.5 to 12 bar.
Tail piece connections enable easy in situ installation. ½" to 2" BSP
connections.
D15P
Pressure reducing valve with balanced seat. Protects water
installations against excessive pressure. Powder coated cast iron construction offers
maximum resistance to corrosion. Non Rising stem enables compact installation. Flanged
connections to PN16, sizes DN50 to DN200. Maximum inlet pressure 16 bar, outlet pressure
1.5 to 6 bar.
D15NP
Pressure reducing valve with balanced seat. Protects water
installations against excessive pressure. Powder coated cast iron construction offers
maximum resistance to corrosion. Non Rising stem enables compact installation. Flanged
connections to PN16, sizes DN50 to DN200. Maximum inlet pressure 16 bar, outlet pressure
0.2 to 2 bar.
D22
Pressure reducing valve with piston balanced seat. For
compressed air applications. Special versions with Viton seals available. Maximum inlet
pressure 40 bar outlet pressure 1 to 10 bar. Connection sizes ¼" to 2" female
BSP.
SAFETY
Honeywell manufactures and supplies a range of safety
control valves for various applications. Strict regulations apply to the construction,
installation and operation of pressurised water systems and appliances. Honeywell controls
are designed to ensure protection against over heating and excess
pressurisation.
See also the section on Unvented
Cylinder Controls
SM152
Expansion Valve
The SM152 provides expansion relief in Unvented hot water
packages or other pressurised water applications. The SM152 is
factory set to any pressure between 1.5 bar and 10 bar. The
valve is suitable for installation in the cold inlet and has a
male inlet connection and a female outlet connection. Size
available are ½" BSP.
RV284
Single Check Valve
The RV284 conform to BS6282 Part 1 and is WRAS Approved.
These valves can be used on either cold or hot water up to 90ºC.
The RV284 is used to prevent the contamination of water by
backflow or cross flow in plumbing systems.
THERMOSTATIC
VALVES
TM200VP
The Honeywell TM200V thermostatic mixing valve is approved
to the requirements of the NHS Model Engineering.
Specification D08, for thermostatic mixing valves to reduce
the risk of emitting water at an unsafe temperature.
The TM200V is WRAS Approved for the following designations,
LP-W Low Pressure Wash hand basins
LP-B Low Pressure Bidets
LP-S Low Pressure Showers
HP-W High Pressure Wash hand basins
HP-B High Pressure Bidets
HP-S High Pressure Showers
HP-T44 High Pressure Baths (Unattended)
The TM200VP is particularly suited for use in areas such as
sheltered housing, hospitals, nursing homes, schools, playgroups, motorway service
stations and hotels etc. where high water temperatures can lead to scalding.
Honeywell is a founder member of the Thermostatic Mixing
Valve Association TMVA, set up to promote awareness of the dangers of high water
temperatures. Further information available from www.tmva.org.uk
The Child
Accident Prevention Trust have produced a fact sheet after
revealing that every year 500 children are admitted to hospital
and another 2,000 per year attend their local accident and
emergency departments as a result of bath water scalds.
To see a copy of
the fact sheet please go to the following website;
http://www.capt.org.uk/FAQ/default.htm
RK200E
The RK200E is a flexible hose with 15mm connections to aid
the retrofit installation of the TM200V.
RK200H
The RK200H is a flexible hose with 22mm connections to aid
the retrofit installation of the TM200V.
UNVENTED
CYLINDER CONTROLS
| Item |
Description |
Installation
Manual |
Data
Sheet |
| ICSxx |
Inlet
Control Group |
Not
Available |
NA |
| TPxxx |
Temperature
and Pressure Relief Valve |
Not
Available |
Read |
Inlet
Control Group
An Inlet Control Group consists of
a Pressure Reducing Valve, Check valve and Expansion relief valve,
provided as one assembly.
The Inlet Control Group is fitted
on the mains cold water supply to an unvented cylinder to control
pressure, protect against backflow conditions and permit excess
pressure and temperature to be relieved. Honeywell can provide
alternate solutions in 22mm and 28mm sizes, to meet various market
requirements.
Temperature
and Pressure Relief Valves
Available with either 1/2",
15mm or 3/4" connections, the temperature and pressure relief
valve is fitted to the hot water cylinder so as the temperature
probe is submersed in the water at the hottest point. The
Temperature and Pressure relief valve should be factory fitted by
the manufacturer of the unvented cylinder and is a requirement of
the Building Regulations G3.
MODUS
Honeywell is a member of MODUS,
manufacturers of Domestic Unvented Systems and in common with all
Modus members will provide advice on all matters relating to the
installation of Unvented hot water cylinders.
Click
here to visit the Modus website
|